With responsible good quality method, good status and excellent client services, the series of solutions produced by our company are exported to lots of countries and regions for Non Contact Level Sensor, Turbidity Analyzer, Turbine Type Flow Meter, We warmly welcome all interested customers to contact us for more information.
Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure Detail:

  • Specification
 Product Easy Fuzzy PID Regulator
 Model SUP-1300
 Display Dual-screen LED display
 Dimension A. 160*80*110mm
B. 80*160*110mm
C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F. 72*72*110mm
H. 48*48*110mm
Measurement accuracy ±0.3%FS
Transmission output Analog output—-4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V
Alarm Output With upper and lower limit alarm function, with alarm return difference setting;capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistive load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supply AC/DC100~240V (Frequency 50/60Hz) Power consumption≤5W
DC12~36V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing

 

  • Introduction

SUP-1300 series easy fuzzy PID regulator adopts fuzzy PID formula for easy operation with measurement precision of 0.3%; 7 types of dimensions available, 33 types of signal input available; applicable to measurement of industrial process quantifiers including temperature, pressure, flow, liquid level, and humidity etc. Combined with all kinds of executors, it’s capable of PID regulation and control to electric heating appliances, electromagnetic and electric control valve. Supporting 2-way alarm, 1-way control output or RS485 communication interface adopting standard MODBUS protocol, 1-way DC24V feed output; photoelectric isolation between input, output and power end; 100-240V AC/DC or 20-29V DC switch power supply; standard snap-in installation; operating temperature: 0-50℃, relative humidity: 5-85% RH without coagulation.

Profile of Display Panel

(1) PV Display (measured value)
(2) SV Display
Display parameters like input type in measurement mode;
Display setting value in parameters setting mode;
(3) Primary alarm (AL1) and secondary alarm indication lamp, running lamp (RUN) and output lamp (OUT);
(4) Confirmation
(5) Shift
(6) Decrease
(7) Increase
How to get the core out of shell:
The core of instrument can be taken out from the shell. Push buckles on both sides of the front panel aside, and push the front panel to separate core and shell. For installation, put the core into the shell and lock it with buckles to meet protection standard.

High brightness display
Dual-screen three-digit LED digital display PC mask
High transparency, smooth surface
Good aging resistance

Touch button
Use high-quality silicone buttons
Sensitive operation and long service life
Good touch and good recovery

Ventilation and heat dissipation
Open holes on both sides, convection ventilation to ensure long-term high temperature operation of the instrument

Limit cover protection
Wiring diagram—-to ensure correct wiring
Wiring cover — to ensure wiring safety

Embedded installation
Dial hole, standard size
Fastened by buckle, easy to install

Multiple output types available

  • 4~20mA(RL≤500Ω)
  • 1~5V(RL≥250kΩ)
  • 0~10mA(RL≤1KΩ)
  • 0~5V(RL≥250kΩ)
  • 0~20mA(RL≤500Ω)
  • 0~10V(RL≥4kΩ)
  • Relay node output
  • SCR zero-crossing trigger pulse output
  • Solid state relay drive voltage output

Multiple control methods are available

  • Positive-acting refrigeration control
  • Reaction heating control
  • Position control
  • Fuzzy PID adjustment control

Product detail pictures:

Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure detail pictures

Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure detail pictures

Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure detail pictures

Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure detail pictures

Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure detail pictures


Related Product Guide:

We'll make every effort and hard work to be superb and excellent, and speed up our steps for standing inside the rank of intercontinental top-grade and high-tech enterprises for Factory source Turbidity Analyzer - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure , The product will supply to all over the world, such as: Denmark, Puerto Rico, Munich, Welcome any of your inquiries and concerns for our products. We look forward to establishing a long-term business relationship with you in the near future. Contact us today. We are the first business partner for you!
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Norma from Washington - 2018.12.11 14:13
    The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Lydia from Berlin - 2017.03.08 14:45