  • Top Suppliers Fluid Flow Meter - SUP-LDG-C Electromagnetic flow meter – Sinomeasure

    Top Suppliers Fluid Flow Meter - SUP-LDG-C Electromagnetic flow meter – Sinomeasure

    Specification Product: Electromagnetic flow meter Model: SUP-LDG-C Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.3%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Sp...
  • China New Product Water Flow Meter Pulse Output - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure

    China New Product Water Flow Meter Pulse Output - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure

    Measuring principle A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression: f=StV/d In the formula: f – Karman vortex f...
  • Top Suppliers Online Tds Meter For Ro Plant - SUP-R8000D Paperless recorder – Sinomeasure

    Top Suppliers Online Tds Meter For Ro Plant - SUP-R8000D Paperless recorder – Sinomeasure

    Specification Input signal type Ⅱ standard signal: (0 ~ 10) mA, (0 ~ 5) V Ⅲ standard signal: (4 ~ 20) mA, (1 ~ 5) V 14 thermocouples: B, E, J, K, S, T, R, N, WRe5-26, WRe3-25, BA1, BA2, F1, F2 3 kinds of thermal resistance: Pt100, Cu50, JPt100 Other signals (0-20) mv, (0-100) mv, (-10-10) v, (0-10) v, (-5-5) v, (0-1) v, ) V, resistance 0-350Ω, frequency 0-10KHZ Isolation Isolation between channels and ground Resistant to heat greater than 500VAC, isolation between channel...
  • Low MOQ for Portable Ultrasonic Flow Meter – SUP-LWGY Turbine flowmeter thread connection – Sinomeasure

    Low MOQ for Portable Ultrasonic Flow Meter – SUP-LWGY Turbine flowmeter thread connection – Sinomeasure

    Specification  Product  Turbine flowmeter  Model  SUP-LWGY  Diameter Nominal  DN4~DN100  Nominal Pressure  6.3MPa  Accuracy  0.5%R, 1.0%R  Medium viscosity  Less than 5×10-6m2/s  (for the liquid with >5×10-6m2/s,  the flowermeter needs to be calibrated before using)  Medium Temperature  -20℃~+120℃  Power Supply  3.6V lithium battery; 12VDC; 24VDC  Output Signal  Pulse, 4-20mA, RS485 Modbus  Ingress protection  IP65   Introduction SUP-LWGY series l...
  • Factory wholesale Ultrasonic Level Transmitter Price - SUP-DP Ultrasonic level transmitter – Sinomeasure

    Factory wholesale Ultrasonic Level Transmitter Price - SUP-DP Ultrasonic level transmitter – Sinomeasure

    Specification  Product Ultrasonic level transmitter  Model SUP-DP  Measure range 5m、10m、15m、20m、30m、40m、50m  Blind zone <0.3-2.5m(different for range)  Accuracy 1%  Display LCD  Output (optional) Four-wire 4~20mA/510Ωload Two-wire 4~20mA/250Ω load 2 relays (AC 250V/ 8A or DC 30V/ 5A  )  Temperature LCD: -20~+60℃; Probe: -20~+80℃  Power supply 24VDC (Optional: 220V AC+15%  50Hz)  Power consumption <1.5W  Protection degree IP65   Introd...
  • 2022 Good Quality Magmeter Flow Meter - Magnetic flow transmitter – Sinomeasure

    2022 Good Quality Magmeter Flow Meter - Magnetic flow transmitter – Sinomeasure

    Specification Measuring principle Faraday’s law of induction Function Instantaneous flow rate, flow velocity, mass flow (when the density is constant) Modular structure Measuring system is composed of a measuring sensor and a signal converter Serial communication RS485 Output Current (4-20 mA), pulse frequency, mode switch value Function Empty pipe identification, electrode pollution Display user interface Graphic display Monochrome liquid crystal display, white bac...
  • Factory Outlets 4 20ma Loop Isolator - SUP-R9600 Paperless recorder up to 18 channels unviersal input – Sinomeasure

    Factory Outlets 4 20ma Loop Isolator - SUP-R9600 Paperless recorder up to 18 channels unviersal input – Sinomeasure

    Specification  Product Paperless recorder  Model SUP-R9600  Display 3.5 inch TFT true color LCD screen  Dimension Dimension:96mm×96mm×96mm Opening Size:92mm×92mm  Thickness of mounted panel 1.5mm~6.0mm  Weight 0.37kg  Power supply (176~264)VAC,47~63Hz  Internal storage 48M bytes Flash  External storage U disk support (standard USB2.0 communication interface)  Maximum power consumption 20VA  Relative humidity (10~85)%RH(No condensation)  Operating temperature ...
  • Cheapest Price Dissolved Oxygen Transmitter - SUP-110T Economic 3-digit Single-loop Digital Display Controller – Sinomeasure

    Cheapest Price Dissolved Oxygen Transmitter - SUP-110T Economic 3-digit Single-loop Digital Display Controller – Sinomeasure

    Specification  Product Digital Single-loop digital display controller  Model SUP-110T  Display Dual-screen LED display  Dimension C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm H. 48*48*110mm Measurement accuracy ±0.3%FS Analog output Analog output—-4-20mA、1-5V(RL≤500Ω)、1-5V(RL≥250kΩ) Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay contact capacity: AC125V/0.5A(small)DC24V/0.5A(small)(Resistance C ...
  • Super Lowest Price Gas Flow Meter - SUP-LUGB Vortex flowmeter with temperature & pressure compensation – Sinomeasure

    Super Lowest Price Gas Flow Meter - SUP-LUGB Vortex flowmeter with temperature & pressure compensation – Sinomeasure

    Measuring principle Vortex flow meter work on the principle of generated vortex and relation between vortex and flow by theory of Karman and Strouhal, which specialize in measurement of steam, gas and liquid of lower viscosity. As shown in below illustration, medium flows through bluff body and then vortex is generated, vortices are alternately formed on both sides with opposite directions of rotation, Vortices frequency is directly proportional to medium velocity. Through numbers of vortic...
  • Good quality Radar Water Level Sensor - SUP-P260-M4 Submersible level and temperature meter – Sinomeasure

    Good quality Radar Water Level Sensor - SUP-P260-M4 Submersible level and temperature meter – Sinomeasure

    Specification Product Level and temperature meter  Model SUP-P260-M4  Measuring range Level:(0…100)m Temperature :(0…50)℃  Accuracy Temperature :1.5%FS Level:0.5%FS  Compensation temperature 0…50℃  Output signal RS485/4~20mA/0~5V/1~5V  Medium temperature -20…65℃  Power supply 12…30VDC  Ingress Protection IP68   Introduction Application Description
  • Top Quality 4 20ma Signal Generator - SUP-R8000D Paperless recorder – Sinomeasure

    Top Quality 4 20ma Signal Generator - SUP-R8000D Paperless recorder – Sinomeasure

    Specification Input signal type Ⅱ standard signal: (0 ~ 10) mA, (0 ~ 5) V Ⅲ standard signal: (4 ~ 20) mA, (1 ~ 5) V 14 thermocouples: B, E, J, K, S, T, R, N, WRe5-26, WRe3-25, BA1, BA2, F1, F2 3 kinds of thermal resistance: Pt100, Cu50, JPt100 Other signals (0-20) mv, (0-100) mv, (-10-10) v, (0-10) v, (-5-5) v, (0-1) v, ) V, resistance 0-350Ω, frequency 0-10KHZ Isolation Isolation between channels and ground Resistant to heat greater than 500VAC, isolation between channel...
  • Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure

    Professional China Magnetic Water Flow Sensor - Sinomeasure Multi-parameter analyzer – Sinomeasure

    Item Index Value System working power (220±22)V AC,(50±1)Hz Power 30W Cabinet size 800mm*506mm*180mm (standard version) Weight about 15Kg Storage temperature 4℃~+50℃ Working temperature 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) Working humidity ≤95%RH (no condensation) Inlet flow 500~1000 mL/min Inlet pressure < 3kg/cm³ Communication interface RS485 Modbus RTU communication protocol + wireless interface Turbidity Range 0-1NTU / 0...