-
Good Quality Hydrostatic Level Sensor - SUP-RD902T 26GHz Radar level meter – Sinomeasure
pecification Product Radar level meter Model SUP-RD902T Measure range 0-20 meters Application Liquid Process Connection Thread, Flange Medium Temperature -40℃~130℃(Standard type), -40℃~250℃(High temp type) Process Pressure -0.1~2.0MPa Accuracy ±10mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD902T Non-contact radar with simple commissioning... -
Well-designed 1 Inch Flow Meter - SUP-LDG-C Electromagnetic flow meter – Sinomeasure
Specification Product: Electromagnetic flow meter Model: SUP-LDG-C Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.3%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Sp... -
PriceList for Level Transducer - SUP-RD908 Radar level meter for river – Sinomeasure
Specification Product Radar level meter Model SUP-RD908 Measure range 0-30 meters Application Rivers, Lakes, Shoal Process Connection Thread G1½ A”/frame /flange Medium Temperature -20℃~100℃ Process Pressure Normal pressure Accuracy ±3mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD908 Radar level meter is a safe solution even under ex... -
Factory Free sample Vortex Type Flow Meter - SUP-LDG Sanitary electromagnetic flowmeter for food processing – Sinomeasure
Specification Product Sanitary type electromagnetic flowmeter Model SUP-LDGS Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Repetitiveness 0.2% Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient temperature -10℃~55℃ Power supply ... -
China OEM Water Tank Level Monitor - SUP-P260-M3 Submersible level meter – Sinomeasure
Specification Product Water level sensor Model SUP-P260-M3 Measuring range 0 ~ 5m Display resolution 0.5% Ambient temperature -10 ~ 85 ℃ Output signal 4-20mA, 0-5V, 0-10V Pressure overload 150%FS Power supply 24VDC; 12VDC Medium temperature -40 ℃ ~ 60 ℃ Overall material Core: 316L; Shell: 304 material Introduction Application Description -
OEM Supply Ph Ec Controller - SUP-1300 Easy Fuzzy PID Regulator – Sinomeasure
Specification Product Easy Fuzzy PID Regulator Model SUP-1300 Display Dual-screen LED display Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm H. 48*48*110mm Measurement accuracy ±0.3%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output With upper and lower limit alarm function, with alarm return difference setting;capacity: AC125V/0.5A(small)DC24V/0.5A(small)(Resistiv... -
Hot sale Industrial Water Flow Meter - SUP-LDG Stainless steel body electromagnetic flowmeter – Sinomeasure
Specification Product Electromagnetic flowmeter Model SUP-LDG Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Liner material PFA,F46,Neoprene,PTFE,FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient Temperature -10℃~60℃ Electrical conductivity Water 20μS/cm other medium 5μS/cm... -
2022 Good Quality Magmeter Flow Meter - SUP-LWGY Turbine flow sensor thread connection – Sinomeasure
Specification Product: Turbine flow sensor Model: SUP-LWGY Diameter Nominal: DN4~DN100 Nominal Pressure: 6.3MPa Accuracy: 0.5%R, 1.0%R Medium Temperature: -20℃~+120℃ Power Supply: 3.6V lithium battery; 12VDC; 24VDC Output Signal: Pulse, 4-20mA, RS485(With transmitter) Ingress protection: IP65 Principle The fluid flows through the turbine flow sensor shell. Because the blade of the impeller has a certain angle with the flow direction, the impulse of the fluid makes the blade... -
Professional China Non Contact Liquid Level Sensor - SUP-RD701 Guided wave radar level meter – Sinomeasure
Specification Product Guided wave radar level meter Model SUP-RD701 Measure range 0-30 meters Application Liquids and bulk solids Process Connection Thread/ Flange Medium Temperature -40℃~130℃(Standard)/-40~250℃(High temp) Process Pressure -0.1 ~ 4MPa Accuracy ±10mm Protection Grade IP67 Frequency Range 500MHz-1.8GHz Signal Output 4-20mA (Two-wire/Four) RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction Product S... -
Super Lowest Price Gas Flow Meter - SUP-LDG Sanitary electromagnetic flowmeter for food processing – Sinomeasure
Specification Product Sanitary type electromagnetic flowmeter Model SUP-LDGS Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Repetitiveness 0.2% Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient temperature -10℃~55℃ Power supply ... -
OEM Customized Turbine Type Flow Meter - SUP-1158S Wall mounted ultrasonic flowmeter – Sinomeasure
Specification Product Wall-mounted ultrasonic flowmeter Model SUP-1158S Pipe Size DN32-DN6000 Accuracy ±1% Signal output 1 way 4-20mA output 1 way OCT pulse output 1 way replay output Interface RS485, support MODBUS Liquid Types Virtually all liquids Working Temperature Convertor: -20~60℃;Flow Transducer:-30~160℃ Working humidity Convertor:85%RH Power Supply DC8~36V or AC85~264V(optional) Date Logger Built-in data logger can store over 2000 lines of data... -
Online Exporter Steam Flow Meter Price - SUP-LZ Metal tube rotameter – Sinomeasure
Specification Porduct Metal Tube Rotameter Model SUP-LZ Range Water (20℃) (01~200000) L/h Air (20,0.1013MPa) (0.03~3000) m³/h Range ratio Standard 10:1 Optional 20:1 Accuracy Standard: 1.5% Optional:1% Gas: 1.5% Pressure standard:DN15~DN50≤4.0MPa DN80~DN200≤1.6MPa Optioanl: DN15~DN50≤32MPa DN80~DN200≤16MPa Connection Flange,Clamp,Thread, Sanity thread Medium temperature Standard:-20℃~120℃ PTFE 0℃~80℃ High temp:120℃~450℃ low temp: -80℃~-20℃ Environ...