-
Super Lowest Price Inline Ph Sensor - SUP-R6000F Paperless recorder – Sinomeasure
Specification Product Paperless recorder Model SUP-R6000F Display 7 inch TFT display screen Input Up to 36 channels of universal input Relay output 2A/250VAC, Max 8 channels Weight 1.06kg Communication RS485, Modbus-RTU Internal memory 128 Mbytes Flash Power supply (176~264)VAC,47~63Hz Dimensions 193*162*144mm Shorter mounting depth 144mm DIN panel cutout 138*138mm Introduction Dimension -
China Supplier Paperless Recorder - SUP-825-J Signal Calibrator 0.075% high accuracy – Sinomeasure
Specification General Specifications Operating temperature -10℃~55℃ Storage temperature -20℃~70℃ Relative Humidity (%RH operating without condensation) 90%(10℃~30℃) 75%(30℃~40℃) 45%(40℃~50℃) 35%(50℃~55℃) Uncontrolled<10℃ EMC EN55022, EN55024 Vibration Random, 2g, 5 to 500Hz Concussion 30g, 11ms, half sine bow wave Power requirement 4 AA Ni-MH, Ni-Cd batteries Size 215mm×109mm×44.5mm Weight About 500g DC Voltage Range Accuracy Measurement (0~100)m... -
Manufactur standard Pulse Flow Meter - SUP-LZ Metal tube rotameter – Sinomeasure
Specification Porduct Metal Tube Rotameter Model SUP-LZ Range Water (20℃) (01~200000) L/h Air (20,0.1013MPa) (0.03~3000) m³/h Range ratio Standard 10:1 Optional 20:1 Accuracy Standard: 1.5% Optional:1% Gas: 1.5% Pressure standard:DN15~DN50≤4.0MPa DN80~DN200≤1.6MPa Optioanl: DN15~DN50≤32MPa DN80~DN200≤16MPa Connection Flange,Clamp,Thread, Sanity thread Medium temperature Standard:-20℃~120℃ PTFE 0℃~80℃ High temp:120℃~450℃ low temp: -80℃~-20℃ Environ... -
2022 wholesale price Electromagnetic Flow - SUP-603S Temperature signal isolator – Sinomeasure
Specification • Input signal type: Thermocouple: K, E, S, B, J, T, R, N and WRe3-WRe25, WRe5-WRe26, etc.; Thermal resistance: two-/three-wire system thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, etc.) The type and range of input signal can be determined at the time of ordering or self-programmed. • Output signal type: DC: 0(4)mA~20mA;0mA~10mA; DC voltage: 0(1)V~5V; 0V~10V; Other signal types may be customized as required, see the product label for the specific signal types; • O... -
Super Lowest Price Gas Flow Meter - SUP-LDG Carbon steel body electromagnetic flow meter – Sinomeasure
Specification Product: Electromagnetic flowmeter Model: SUP-LDG Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.5%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Split... -
Best Price for Flow Meter Pulse Output - SUP-LDG-C Electromagnetic flow meter – Sinomeasure
Specification Product: Electromagnetic flow meter Model: SUP-LDG-C Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.3%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Sp... -
2022 High quality Electromagnetic Flow Metre - SUP-2100 Single-loop digital display controller – Sinomeasure
Specification Product Single-loop digital display controller Model SUP-2100 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F.72*72*110mm H. 48*48*110mm K.160*80*110mm L. 80*160*110mm M. 96*96*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC12... -
2022 High quality Pressure Transducer - SUP-PX300 Pressure transmitter with display – Sinomeasure
Specification Product Pressure transmitter Model SUP-PX300 Measure range -0.1…0/0.01…60Mpa Indication resolution 0.5% Working temperature -20-85°C Output signal 4-20ma analog output Pressure type Gauge pressure; Absolute pressure Measure medium Liquid; Gas; Oil etc Pressure overload 0.035…10MPa(150%FS)10…60MPa(125%FS) Power 10-32V (4…20mA);12-32V (0…10V);8-32V (RS485) Introduction Pressure transmitter is a common sensor in... -
factory Outlets for Liquid Flowmeters - Magnetic flow transmitter – Sinomeasure
Specification Measuring principle Faraday’s law of induction Function Instantaneous flow rate, flow velocity, mass flow (when the density is constant) Modular structure Measuring system is composed of a measuring sensor and a signal converter Serial communication RS485 Output Current (4-20 mA), pulse frequency, mode switch value Function Empty pipe identification, electrode pollution Display user interface Graphic display Monochrome liquid crystal display, white bac... -
Low price for Vortex Flow Meter - Magnetic flow transmitter – Sinomeasure
Specification Measuring principle Faraday’s law of induction Function Instantaneous flow rate, flow velocity, mass flow (when the density is constant) Modular structure Measuring system is composed of a measuring sensor and a signal converter Serial communication RS485 Output Current (4-20 mA), pulse frequency, mode switch value Function Empty pipe identification, electrode pollution Display user interface Graphic display Monochrome liquid crystal display, white bac... -
Free sample for Wastewater Level Sensor - SUP-ZP Ultrasonic level transmitter – Sinomeasure
Specification Product Ultrasonic level transmitter Model SUP-ZP Measure range 5、10、15m Blind zone <0.4-0.6m(different for range) Accuracy 0.5%F.S Display OLED Output (optional) 4~20mA RL>600Ω(standard) RS485 2 relays (AC: 5A 250V DC: 10A 24V) Material ABS, PP Electrical interface M20X1.5 Power supply 12-24VDC, 18-28VDC (two Wire), 220VAC Power consumption <1.5W Protection degree IP65(others optional) Introduction Application... -
China OEM Water Tank Level Monitor - SUP-P260G High temp type submersible level meter – Sinomeasure
Advantages Compact shape, accurate measurement. According to fluid mechanics, the use of cylindrical arc shape, the effective media to the impact of the probe down to reduce the impact of probe shaking on the measurement stability Multiple waterproof and dustproof. The first protective layer: 316L sensor diaphragm, seamless connection, to ensure that the lead and the sensor probe waterproof; Second protective layer: pressure pipe design, to ensure that the protective layer and the lead pa...