100% Original Inline Ph Meter - SUP-R200D Paperless recorder up to 4 channels unviersal input – Sinomeasure
Specification Product Paperless recorder Model SUP-R200D Inputs channel 1~4channels Input 0-10 mA, 4-20 Ma,0-5 V, 1-5 V, 0-20 mV. 0-100 mV, Thermocrouple:B,E,J,K,S,T,R,N,F1,F2,WRE RTD:Pt100,Cu50,BA1,BA2 Accuracy 0.2%FS Input impendance Standard current signal input 250 ohm,other signal input>20M ohm Power supply AC voltage 176-240VAC Alarm output 250VAC,3A relay Communication Interface:RS-485 or RS-232 Sampling period 1s Record 1s/2s/5s/10s/15s/30s... -
Low price for Ph Controller - SUP-110T Economic 3-digit Single-loop Digital Display Controller – Sinomeasure
Specification Product Digital Single-loop digital display controller Model SUP-110T Display Dual-screen LED display Dimension C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm H. 48*48*110mm Measurement accuracy ±0.3%FS Analog output Analog output—-4-20mA、1-5V(RL≤500Ω)、1-5V(RL≥250kΩ) Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay contact capacity: AC125V/0.5A(small)DC24V/0.5A(small)(Resistance C ... -
High Quality Flow Meter - SUP-LUGB Vortex flowmeter with temperature & pressure compensation – Sinomeasure
Measuring principle Vortex flow meter work on the principle of generated vortex and relation between vortex and flow by theory of Karman and Strouhal, which specialize in measurement of steam, gas and liquid of lower viscosity. As shown in below illustration, medium flows through bluff body and then vortex is generated, vortices are alternately formed on both sides with opposite directions of rotation, Vortices frequency is directly proportional to medium velocity. Through numbers of vortic... -
Low price for Ph Controller - SUP-2200 Dual-loop digital display controller – Sinomeasure
Specification Products Dual-loop digital display controller Model no. SUP-2200 Display Dual-screen LED display Dimension A.160*80*110 mm B. 80*160*110 mm C. 96*96*110 mm D. 96*48*110 mm E. 48*96*110 mm F. 72*72*110 mm K. 160*80*110 mm L. 80*160*110 mm Accuracy ±0.2%FS Transmission output Analog output—-Analog output—-4-20mA、1-5v、 0-10mA、0-20mA、0-5V、0-10V Relay Output ALM—With upper and lower limit alarm function, with alarm return difference setting;Relay contact ... -
Best Price on Digital Liquid Flow Meter - SUP-LUGB Vortex flowmeter without temperature & pressure compensation – Sinomeasure
Measuring principle A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression: f=StV/d In the formula: f – Karman vortex f... -
Factory wholesale Ultrasonic Level Transmitter Price - SUP-DFG Ultrasonic level transmitter – Sinomeasure
SUP-DFG split ultrasonic liquid level gauge is a digital liquid level gauge controlled by microprocessor. By sensor The ultrasonic pulse generated by (transducer) is sent out in the measurement. After the surface acoustic wave is reflected by the same sensor or ultrasonic receiver receiving the liquid, the piezoelectric crystal or magnetostrictive device converts the transmitted and received acoustic wave into electrical signal to calculate the time between the sensor surface and the measured... -
One of Hottest for Do Meter For Aquaculture - SUP-2700 Multi-loop digital display controller – Sinomeasure
Specification Product Multi-loop digital display controller Model SUP-2700 Dimension A. 160*80*136mm B. 80*160*136mm C. 96*96*136mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output Over-range display value flashing alarm function With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC220V/2A(big)DC24V/2A(big)(Resistive load) Note: When the load exceed... -
One of Hottest for Pipe Flow Meter - SUP-LWGY Turbine flow sensor thread connection – Sinomeasure
Specification Product: Turbine flow sensor Model: SUP-LWGY Diameter Nominal: DN4~DN100 Nominal Pressure: 6.3MPa Accuracy: 0.5%R, 1.0%R Medium Temperature: -20℃~+120℃ Power Supply: 3.6V lithium battery; 12VDC; 24VDC Output Signal: Pulse, 4-20mA, RS485(With transmitter) Ingress protection: IP65 Principle The fluid flows through the turbine flow sensor shell. Because the blade of the impeller has a certain angle with the flow direction, the impulse of the fluid makes the blade... -
Wholesale Dealers of Low Flow Flow Meter - SUP-LWGY Turbine flowmeter flange connection – Sinomeasure
Specification Products Turbine flow meter Model no. LWGY-SUP Diameter DN4~DN200 Pressure 1.0MPa~6.3MPa Accuracy 0.5%R(standard), 1.0%R Medium viscosity Less than 5×10-6m2/s (for the liquid with >5×10-6m2/s, the flowermeter needs to be calibrated before using) Temperature -20 to 120℃ Power Supply 3.6V lithium battery; 12VDC; 24VDC Output Pulse, 4-20mA, RS485 Modbus Ingress protection IP65 Introduction LWGY-SUP Turbine flow meter... -
Top Quality 4 20ma Signal Generator - SUP-603S Temperature signal isolator – Sinomeasure
Specification • Input signal type: Thermocouple: K, E, S, B, J, T, R, N and WRe3-WRe25, WRe5-WRe26, etc.; Thermal resistance: two-/three-wire system thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, etc.) The type and range of input signal can be determined at the time of ordering or self-programmed. • Output signal type: DC: 0(4)mA~20mA;0mA~10mA; DC voltage: 0(1)V~5V; 0V~10V; Other signal types may be customized as required, see the product label for the specific signal types; • O... -
Chinese wholesale Ultrasonic Level Transducer - SUP-RD908 Radar level meter for river – Sinomeasure
Specification Product Radar level meter Model SUP-RD908 Measure range 0-30 meters Application Rivers, Lakes, Shoal Process Connection Thread G1½ A”/frame /flange Medium Temperature -20℃~100℃ Process Pressure Normal pressure Accuracy ±3mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD908 Radar level meter is a safe solution even under ex... -
Wholesale Radar Type Level Transmitter - SUP-RD902T 26GHz Radar level meter – Sinomeasure
pecification Product Radar level meter Model SUP-RD902T Measure range 0-20 meters Application Liquid Process Connection Thread, Flange Medium Temperature -40℃~130℃(Standard type), -40℃~250℃(High temp type) Process Pressure -0.1~2.0MPa Accuracy ±10mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD902T Non-contact radar with simple commissioning...