OEM China 2 Inch Flow Meter - SUP-LDG-C Electromagnetic flow meter – Sinomeasure
Specification Product: Electromagnetic flow meter Model: SUP-LDG-C Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.3%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Sp... -
2022 China New Design Ultrasonic Meter - SUP-2100 Single-loop digital display controller – Sinomeasure
Specification Product Single-loop digital display controller Model SUP-2100 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F.72*72*110mm H. 48*48*110mm K.160*80*110mm L. 80*160*110mm M. 96*96*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC12... -
Factory Free sample Vortex Type Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure
Measuring principle A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression: f=(St*V)/c*D Installation Wafer connection: ... -
High Quality Pressure Sensor - SUP-P450 2088 Membrane pressure transmitter – Sinomeasure
Specification Product Pressure transmitter Model SUP-P450 Measure range -0.1~0 to 0 ~ 40MPa Indication resolution 0.5% Ambient temperature -10 ~ 85 ℃ Output signal 4-20mA analog output Pressure type Gauge pressure; Absolute pressure Measure medium Liquid; Gas; Oil etc Pressure overload 150%FS Power DC24 Introduction SUP-P400 Digital Smart LED/LCD display with shell Industrial Pressure Transmitter -
Hot Selling for Process Calibrator - SUP-R200D Paperless recorder up to 4 channels unviersal input – Sinomeasure
Specification Product Paperless recorder Model SUP-R200D Inputs channel 1~4channels Input 0-10 mA, 4-20 Ma,0-5 V, 1-5 V, 0-20 mV. 0-100 mV, Thermocrouple:B,E,J,K,S,T,R,N,F1,F2,WRE RTD:Pt100,Cu50,BA1,BA2 Accuracy 0.2%FS Input impendance Standard current signal input 250 ohm,other signal input>20M ohm Power supply AC voltage 176-240VAC Alarm output 250VAC,3A relay Communication Interface:RS-485 or RS-232 Sampling period 1s Record 1s/2s/5s/10s/15s/30s... -
Hot-selling Magnetic Induction Flow Meter - SUP-LWGY Turbine flow sensor thread connection – Sinomeasure
Specification Product: Turbine flow sensor Model: SUP-LWGY Diameter Nominal: DN4~DN100 Nominal Pressure: 6.3MPa Accuracy: 0.5%R, 1.0%R Medium Temperature: -20℃~+120℃ Power Supply: 3.6V lithium battery; 12VDC; 24VDC Output Signal: Pulse, 4-20mA, RS485(With transmitter) Ingress protection: IP65 Principle The fluid flows through the turbine flow sensor shell. Because the blade of the impeller has a certain angle with the flow direction, the impulse of the fluid makes the blade... -
OEM/ODM Manufacturer Ultrasonic Water Flow Meter - SUP-LDG Stainless steel body electromagnetic flowmeter – Sinomeasure
Specification Product Electromagnetic flowmeter Model SUP-LDG Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Liner material PFA,F46,Neoprene,PTFE,FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient Temperature -10℃~60℃ Electrical conductivity Water 20μS/cm other medium 5μS/cm... -
OEM Factory for Level Indicator Transmitter - SUP-RD902T 26GHz Radar level meter – Sinomeasure
pecification Product Radar level meter Model SUP-RD902T Measure range 0-20 meters Application Liquid Process Connection Thread, Flange Medium Temperature -40℃~130℃(Standard type), -40℃~250℃(High temp type) Process Pressure -0.1~2.0MPa Accuracy ±10mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD902T Non-contact radar with simple commissioning... -
2022 Good Quality Magmeter Flow Meter - SUP-LDG Stainless steel body electromagnetic flowmeter – Sinomeasure
Specification Product Electromagnetic flowmeter Model SUP-LDG Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Liner material PFA,F46,Neoprene,PTFE,FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient Temperature -10℃~60℃ Electrical conductivity Water 20μS/cm other medium 5μS/cm... -
China OEM Tds Analyzer - SUP-602S Intelligent signal isolator for voltage/current – Sinomeasure
Advantages • Dielectric strength (leakage current 1mA, with test time of 1 minute): ≥1500VAC (among input/output/power supply) • Insulation resistance: ≥100MΩ (among input/output/power supply) • EMC: EMC conforms to IEC61326-3 • Power supply: DC 18~32V (typical value 24V DC) • Full-load power: Single-channel input, single-channel output 0.6W Single-channel input, double-channel output 1.5W Specification • Allowed input signal: DC: 0(4)mA~20mA;0mA~10mA Other signal type... -
Well-designed 1 Inch Flow Meter - SUP-LWGY Turbine flow sensor thread connection – Sinomeasure
Specification Product: Turbine flow sensor Model: SUP-LWGY Diameter Nominal: DN4~DN100 Nominal Pressure: 6.3MPa Accuracy: 0.5%R, 1.0%R Medium Temperature: -20℃~+120℃ Power Supply: 3.6V lithium battery; 12VDC; 24VDC Output Signal: Pulse, 4-20mA, RS485(With transmitter) Ingress protection: IP65 Principle The fluid flows through the turbine flow sensor shell. Because the blade of the impeller has a certain angle with the flow direction, the impulse of the fluid makes the blade... -
Fast delivery Ph Sensor - SUP-1100 LED Display multi panel meter – Sinomeasure
Specification Product Digital meter/ digital display controller Model SUP-1100 Display Dual-screen LED display Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm G. 48*48*110mm Input Thermocouple B, S, K, E, T, J, R, N, Wre3-25, Wre5-26; RTD: Cu50, Cu53, Cu100, Pt100, BA1, BA2 Analog signal: -100~100mV, 4-20mA, 0-5V, 0-10V, 1-5V Output 4-20mA (RL≤600Ω) RS485 Modbus-RTU Relay output Power supply AC/DC100~240V (AC/5...