Manufacturer for Mag Flow Transmitter - SUP-2600 LCD Flow (Heat) Totalizer / Recorder – Sinomeasure
Specification Product LCD Flow (Heat) Totalizer / Recorder Model SUP-2600 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC125V/0.5A(small) DC24V/0.5A(small)(Resistive load) AC220V/2A(big) DC24V/2A(big)(Resistive load) Note:... -
Chinese Professional Flow Measurement Devices - SUP-R200D Paperless recorder up to 4 channels unviersal input – Sinomeasure
Specification Product Paperless recorder Model SUP-R200D Inputs channel 1~4channels Input 0-10 mA, 4-20 Ma,0-5 V, 1-5 V, 0-20 mV. 0-100 mV, Thermocrouple:B,E,J,K,S,T,R,N,F1,F2,WRE RTD:Pt100,Cu50,BA1,BA2 Accuracy 0.2%FS Input impendance Standard current signal input 250 ohm,other signal input>20M ohm Power supply AC voltage 176-240VAC Alarm output 250VAC,3A relay Communication Interface:RS-485 or RS-232 Sampling period 1s Record 1s/2s/5s/10s/15s/30s... -
Competitive Price for Ultrasonic Flow Meter Sensor - SUP-LDGR Electromagnetic BTU meter – Sinomeasure
Specification Product Electromagnetic BTU meter Model SUP-LDGR Diameter nominal DN15 ~DN1000 Accuracy ±2.5%,(flowrate=1m/s) Working pressure 1.6MPa Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Power supply 100-240VAC,50/60Hz, 22VDC—26VDC Electrical conductivity > 50μS/cm Ingress ... -
Hot New Products Water Tank Sensor – SUP-ORP6050 ORP sensor – Sinomeasure
Specification Product Plastic ORP sensor Model SUP-ORP6050 Measurement range -2000mV ~ 2000mV Membrane resistance ≤10KΩ Stability ±4mV/24h Installation size NPT3/4 Heat resistance 0 ~ 60℃ Pressure resistance 0 ~ 6 Bar Introduction -
Good Quality Hydrostatic Level Sensor - SUP-DP Ultrasonic level transmitter – Sinomeasure
Specification Product Ultrasonic level transmitter Model SUP-DP Measure range 5m、10m、15m、20m、30m、40m、50m Blind zone <0.3-2.5m(different for range) Accuracy 1% Display LCD Output (optional) Four-wire 4~20mA/510Ωload Two-wire 4~20mA/250Ω load 2 relays (AC 250V/ 8A or DC 30V/ 5A ) Temperature LCD: -20~+60℃; Probe: -20~+80℃ Power supply 24VDC (Optional: 220V AC+15% 50Hz) Power consumption <1.5W Protection degree IP65 Introd... -
Cheap PriceList for Fluid Level Sensor - SUP-RD903 Solid material radar level meter – Sinomeasure
Specification Product Radar level meter Model SUP-RD903 Measure range 0-70 meters Application Solid material, strong dust, easy to crystallize, condensation occasion Process Connection Thread, Flange Medium Temperature -40℃~250℃ Process Pressure -0.1 ~ 0.3 MPa (universal flange); -0.1~4.0 MPa (flat flange) Accuracy ±15mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA (Two-wire/Four) RS485/Modbus Power supply 2-wire(DC24V)/... -
Best-Selling Sanitary Flow Meter - SUP-LDG Remote type electromagnetic flowmeter – Sinomeasure
Specification Product Electromagnetic flowmeter Model SUP-LDG Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Liner material PFA,F46,Neoprene,PTFE,FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Power supply 100-240VAC,50/60Hz, 22VDC—26VDC Ambient Temperature -10℃~60℃ Electric... -
Hot New Products Electromagnetic Water Flow Meter - SUP-LDGR Electromagnetic BTU meter – Sinomeasure
Specification Product Electromagnetic BTU meter Model SUP-LDGR Diameter nominal DN15 ~DN1000 Accuracy ±2.5%,(flowrate=1m/s) Working pressure 1.6MPa Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Power supply 100-240VAC,50/60Hz, 22VDC—26VDC Electrical conductivity > 50μS/cm Ingress ... -
OEM Factory for Irrigation Flow Meter - SUP-LDG Sanitary electromagnetic flowmeter for food processing – Sinomeasure
Specification Product Sanitary type electromagnetic flowmeter Model SUP-LDGS Diameter nominal DN15~DN1000 Nominal pressure 0.6~4.0MPa Accuracy ±0.5%,±2mm/s(flowrate<1m/s) Repetitiveness 0.2% Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Ambient temperature -10℃~55℃ Power supply ... -
China Cheap price Electromagnetic Flow Sensor - SUP-1100 LED Display multi panel meter – Sinomeasure
Specification Product Digital meter/ digital display controller Model SUP-1100 Display Dual-screen LED display Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm G. 48*48*110mm Input Thermocouple B, S, K, E, T, J, R, N, Wre3-25, Wre5-26; RTD: Cu50, Cu53, Cu100, Pt100, BA1, BA2 Analog signal: -100~100mV, 4-20mA, 0-5V, 0-10V, 1-5V Output 4-20mA (RL≤600Ω) RS485 Modbus-RTU Relay output Power supply AC/DC100~240V (AC/5... -
Hot Sale for Dissolved Oxygen Analyser - SUP-2100 Single-loop digital display controller – Sinomeasure
Specification Product Single-loop digital display controller Model SUP-2100 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F.72*72*110mm H. 48*48*110mm K.160*80*110mm L. 80*160*110mm M. 96*96*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC12... -
OEM Manufacturer Tds Meter - SUP-R1000 Chart recorder – Sinomeasure
Specification Display LED display Channel 1/2/3/4/5/6/7/8 Input Voltage: (0-5)V/(1-5)V/(0-20)mV/(0-100)mV Electric current : (0-10)mA/(4-20)mA Thermocouple: B,E,K,S,T Thermal resistance: Pt100, Cu50, Cu100 Output Up to 2 current output channels( 4 to 20mA) Sampling period 600ms Chart speed 10mm/h — 1990mm/h Communication RS 232/RS485 (need Customization) Precision 0.2%FS Maximum power consumption Less than 30w Temperature range 0~50C Humidity range 0~85...