Manufacturer for Non Contact Level Sensor - SUP-RD909 70 meters Radar level meter – Sinomeasure
Specification Product Radar level meter Model SUP-RD909 Measure range 0-70 meters Application Rivers, Lakes, Shoal Process Connection Thread G1½ A”/frame /flange Medium Temperature -20℃~100℃ Process Pressure Normal pressure Accuracy ±10mm Protection Grade IP67 / IP65 Frequency Range 26GHz Signal Output 4-20mA (Two-wire/Four) RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD909 Radar level meter ado... -
Hot Sale for Clamp On Water Flow Meter - SUP-LDGR Electromagnetic BTU meter – Sinomeasure
Specification Product Electromagnetic BTU meter Model SUP-LDGR Diameter nominal DN15 ~DN1000 Accuracy ±2.5%,(flowrate=1m/s) Working pressure 1.6MPa Liner material PFA, F46, Neoprene, PTFE, FEP Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature Integral type: -10℃~80℃ Split type: -25℃~180℃ Power supply 100-240VAC,50/60Hz, 22VDC—26VDC Electrical conductivity > 50μS/cm Ingress ... -
Super Lowest Price Inline Ph Sensor - SUP-603S Temperature signal isolator – Sinomeasure
Specification • Input signal type: Thermocouple: K, E, S, B, J, T, R, N and WRe3-WRe25, WRe5-WRe26, etc.; Thermal resistance: two-/three-wire system thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, etc.) The type and range of input signal can be determined at the time of ordering or self-programmed. • Output signal type: DC: 0(4)mA~20mA;0mA~10mA; DC voltage: 0(1)V~5V; 0V~10V; Other signal types may be customized as required, see the product label for the specific signal types; • O... -
Factory Price Water Flow Meter Sensor - SUP-LDG-C Electromagnetic flow meter – Sinomeasure
Specification Product: Electromagnetic flow meter Model: SUP-LDG-C Diameter nominal: DN15~DN1000 Nominal pressure: DN6 – DN80, PN<4.0MPa; DN100 – DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa Accuracy: ±0.3%,±2mm/s(flowrate<1m/s) Repetitiveness: 0.15% Liner material: PFA, F46, Neoprene, PTFE, FEP Electrode material: Stainless steel SUS316, Hastelloy C, Titanium, Tantalum, Platinum-iridium Medium temperature: Integral type: -10℃~80℃; Sp... -
Best quality Flow Measuring Instruments - SUP-2600 LCD Flow (Heat) Totalizer / Recorder – Sinomeasure
Specification Product LCD Flow (Heat) Totalizer / Recorder Model SUP-2600 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC125V/0.5A(small) DC24V/0.5A(small)(Resistive load) AC220V/2A(big) DC24V/2A(big)(Resistive load) Note:... -
Manufactur standard Tds Transmitter - SUP-R200D Paperless recorder up to 4 channels unviersal input – Sinomeasure
Specification Product Paperless recorder Model SUP-R200D Inputs channel 1~4channels Input 0-10 mA, 4-20 Ma,0-5 V, 1-5 V, 0-20 mV. 0-100 mV, Thermocrouple:B,E,J,K,S,T,R,N,F1,F2,WRE RTD:Pt100,Cu50,BA1,BA2 Accuracy 0.2%FS Input impendance Standard current signal input 250 ohm,other signal input>20M ohm Power supply AC voltage 176-240VAC Alarm output 250VAC,3A relay Communication Interface:RS-485 or RS-232 Sampling period 1s Record 1s/2s/5s/10s/15s/30s... -
China OEM Hot Water Flow Meter - SUP-2000H Handheld ultrasonic flowmeter – Sinomeasure
Specification Product Handheld ultrasonic flowmeter Model SUP-2000H Pipe size DN32-DN6000 Accuracy ±1% Totalizer 7-digit totals for net positive and negative flow respectively Liquid types Virtually all liquids Working temperature Convertor: -20~60℃;Flow Transducer:-30~160℃ Working humidity Convertor: 85%RH; Flow transducer: IP67 Display 4×8 Chinese characters or 4×16 English letters Power supply 3 AAA built-in Ni-H batteries Date logger Built-in dat... -
PriceList for Clamp On Ultrasonic Flow Meter - SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure
Measuring principle A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression: f=(St*V)/c*D Installation Wafer connection: ... -
PriceList for Fluid Flow Measurement - SUP-603S Temperature signal isolator – Sinomeasure
Specification • Input signal type: Thermocouple: K, E, S, B, J, T, R, N and WRe3-WRe25, WRe5-WRe26, etc.; Thermal resistance: two-/three-wire system thermal resistance (Pt100, Cu50, Cu100, BA1, BA2, etc.) The type and range of input signal can be determined at the time of ordering or self-programmed. • Output signal type: DC: 0(4)mA~20mA;0mA~10mA; DC voltage: 0(1)V~5V; 0V~10V; Other signal types may be customized as required, see the product label for the specific signal types; • O... -
New Arrival China Wastewater Flow Meter - SUP-LWGY Turbine flowmeter thread connection – Sinomeasure
Specification Product Turbine flowmeter Model SUP-LWGY Diameter Nominal DN4~DN100 Nominal Pressure 6.3MPa Accuracy 0.5%R, 1.0%R Medium viscosity Less than 5×10-6m2/s (for the liquid with >5×10-6m2/s, the flowermeter needs to be calibrated before using) Medium Temperature -20℃~+120℃ Power Supply 3.6V lithium battery; 12VDC; 24VDC Output Signal Pulse, 4-20mA, RS485 Modbus Ingress protection IP65 Introduction SUP-LWGY series l... -
Manufacturing Companies for Level Detector Sensor - SUP-P260-M2 Slurry level sensor submersible level transmitter – Sinomeasure
Features Non-clogging and damage resistant to floating solids Durable 316 SS construction for reliable, long life in harsh environments 1/2 inch NPT threaded connection, allows the unit to be installed in a pipe/conduit Diaphragm is protected from physical damage and turbulence Added weight helps hold transmitter in place Excellent chemical compatibility for wide application use Specification Product Slurry level transmitter Model SUP-P260-B Measuring range 0m-0.5m-100m ... -
Good Wholesale Vendors Dissolved Oxygen Monitor - SUP-110T Economic 3-digit Single-loop Digital Display Controller – Sinomeasure
Specification Product Digital Single-loop digital display controller Model SUP-110T Display Dual-screen LED display Dimension C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm H. 48*48*110mm Measurement accuracy ±0.3%FS Analog output Analog output—-4-20mA、1-5V(RL≤500Ω)、1-5V(RL≥250kΩ) Alarm Output With upper and lower limit alarm function, with alarm return difference setting;Relay contact capacity: AC125V/0.5A(small)DC24V/0.5A(small)(Resistance C ...