Buy Flow Instruments Manufacturers – SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure
Specification Product Artificial Intelligence PID Regulator Model SUP-2300 Dimension A. 160*80*110mm B. 80*160*110mm C. 96*96*110mm D. 96*48*110mm E. 48*96*110mm F. 72*72*110mm H. 48*48*110mm K. 160*80*110mm L. 80*160*110mm M. 96*96*110mm Measurement accuracy ±0.2%FS Transmission output Analog output—-4-20mA、1-5v、 0-10mA、0-5V、0-20mA、0-10V Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity: AC1... -
Online Ph Meters Manufacturer – SUP-PH5011 pH sensor – Sinomeasure
Specification Product Plastic pH sensor Model SUP-PH5011 Measurement range 2 ~ 12 pH Zero potential point 7 ± 0.5 pH Slope > 95% Internal impedance 150-250 MΩ(25℃) Practical response time < 1 min Installation size Upper and Lower 3/4NPT Pipe Thread NTC NTC10K/Pt100/Pt1000 Heat resistance 0 ~ 60℃ for general cables Pressure resistance 0 ~ 4 Bar Connection Low-noise cable Introduction Product adv... -
Buy Online Tds Meter For Ro Plant Factories – SUP-R8000D Paperless recorder – Sinomeasure
Specification Input signal type Ⅱ standard signal: (0 ~ 10) mA, (0 ~ 5) V Ⅲ standard signal: (4 ~ 20) mA, (1 ~ 5) V 14 thermocouples: B, E, J, K, S, T, R, N, WRe5-26, WRe3-25, BA1, BA2, F1, F2 3 kinds of thermal resistance: Pt100, Cu50, JPt100 Other signals (0-20) mv, (0-100) mv, (-10-10) v, (0-10) v, (-5-5) v, (0-1) v, ) V, resistance 0-350Ω, frequency 0-10KHZ Isolation Isolation between channels and ground Resistant to heat greater than 500VAC, isolation between channel... -
Buy In Line Water Flow Meter Manufacturer – SUP-1158-J Wall mounted ultrasonic flowmeter – Sinomeasure
Specification Product Ultrasonic flowmeter Model SUP-1158-J Pipe size DN25-DN1200 Accuracy ±1% Output 4~20mA, 750Ω Communication RS485, MODBUS Flow rate 0.01~5.0 m/s Working temperature Convertor: -10℃~50℃; Flow Transducer: 0℃~80℃ Working humidity Convertor:99%RH; Display 20×2 LCD English letters Power supply 10~36VDC/1A Case material PC/ABS Line 9m(30ft) Handset weight Transmitter: 0.7Kg; Sensor: 0.4Kg Introduction SUP-1158... -
Ph Sensor Manufacturer Factories – SUP-PH8.0 pH ORP meter – Sinomeasure
Specification Product pH meter, pH controller Model SUP-PH8.0 Measure range pH: -2-16 pH, ±0.02pH ORP: -1999 ~1999mV, ±1mV Measuring medium Liquid Input Resistance ≥1012Ω Temp compensation Manual/ Auto temperature compensation Temperature Range 0~60℃, NTC10K or PT1000 Communication RS485, Modbus-RTU Signal output 4-20mA, maximum loop 750Ω, 0.2%FS Power supply 100- 240VDC,50Hz/60Hz,5W Max Relay output 250V, 3A Introductio... -
Buy Differential Pressure Sensor Supplier – SUP-P350K Hygienic pressure transmitter – Sinomeasure
Specification Product Pressure transmitter Model SUP-P350K Measure range -0.1…0…3.5MPa Indication resolution 0.5% Ambient temperature -10 ~ 85 ℃ Output signal 4-20mA analog output Pressure type Gauge pressure; Absolute pressure Measure medium Liquid; Gas; Oil etc Pressure overload 150%FS Power 10-32V (4…20mA);12-32V (0…10V);8-32V (RS485) Introduction Description -
Buy Water Level Sensors For Water Tanks Manufacturer – SUP-RD909 70 meters Radar level meter – Sinomeasure
Specification Product Radar level meter Model SUP-RD909 Measure range 0-70 meters Application Rivers, Lakes, Shoal Process Connection Thread G1½ A”/frame /flange Medium Temperature -20℃~100℃ Process Pressure Normal pressure Accuracy ±10mm Protection Grade IP67 / IP65 Frequency Range 26GHz Signal Output 4-20mA (Two-wire/Four) RS485/Modbus Power supply DC(6~24V)/ Four-wire DC 24V / Two-wire Introduction SUP-RD909 Radar level meter ado... -
Buy Ultrasonic Level Sensor For Tanks Suppliers – SUP-P260-M5 Submersible level meter – Sinomeasure
Specification Product Water level sensor Model SUP-P260-M5 Measuring range 0 ~ 5m Display resolution 0.5% Ambient temperature -10 ~ 85 ℃ Output signal 4-20mA, 0-5V, 0-10V Pressure overload 150%FS Power supply 24VDC; 12VDC Medium temperature -40 ℃ ~ 60 ℃ Overall material Core: 316L; Shell: 304 material Introduction Application Description -
Buy Compressed Air Flow Meter Manufacturers – SUP-LUGB Vortex flowmeter wafer installation – Sinomeasure
Measuring principle A fluid flowing with a certain velocity and passing a fixed obstruction generates vortices. The generation of vortices is known as Karman’s Vortices.The frequency of vortex shedding is a direct linear function of fluid velocity and frequency depends upon the shape and face width of bluff body. Since the width of obstruction and inner diameter of the pipe will be more or less constant, the frequency is given by the expression: f=(St*V)/c*D Installation Wafer connection: ... -
Buy Ultrasonic Level Gauge Manufacturers – SUP-RD905 Solid material radar level meter – Sinomeasure
Specification Product Radar level meter Model SUP-RD905 Measure range 0-30 meters Application Solid particles, powder Process Connection Thread, Flange Medium Temperature -40℃~250℃ Process Pressure -0.1~4.0 MPa (flat flange); -0.1 ~ 0.3 MPa (universal flange) Accuracy ±10mm Protection Grade IP67 Frequency Range 26GHz Signal Output 4-20mA (Two-wire/Four) RS485/Modbus Power supply 2-wire(DC24V)/ 4-wire(DC24V /AC220V) Introduction... -
Ph Meter Controller Factory – pH installation accessories – Sinomeasure
pH installation box -
Buy Absolute Pressure Sensor Factory – SUP-P300G High temperature pressure transmitter – Sinomeasure
Specification Product Pressure transmitter Model SUP-P300G Measuring range -0.1…0/0.01…60Mpa Display resolution 0.5% Medium temperature -50-300°C Working temperature -20-85°C Output signal 4-20mA Analog output Pressure type Gauge pressure; Absolute pressure Measure medium Liquid; Gas; Oil etc Pressure overload 0.035…10MPa(150%FS)10…60MPa(125%FS) Power supply 10-32V (4…20mA);12-32V (0…10V);8-32V (RS485) Introduction ...