Online Ph Sensor Factory – Sinomeasure Multi-parameter analyzer – Sinomeasure
Online Ph Sensor Factory – Sinomeasure Multi-parameter analyzer – Sinomeasure Detail:
Item | Index | Value |
System | working power | (220±22)V AC,(50±1)Hz |
Power | 30W | |
Cabinet size | 800mm*506mm*180mm (standard version) | |
Weight | about 15Kg | |
Storage temperature | 4℃~+50℃ | |
Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
Working humidity | ≤95%RH (no condensation) | |
Inlet flow | 500~1000 mL/min | |
Inlet pressure | < 3kg/cm³ | |
Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
Resolution | 0.001NTU | |
Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
Zero drift | ≤1.5% | |
Indication stability | ≤1.5% | |
Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
Repeatability | ≤3% | |
Response time | ≤60s | |
Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
Resolution | 0.01mg/L | |
Lower detection limit | 0.05mg/L | |
Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
Response time | ≤120 seconds | |
Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
Resolution | 0.01pH, ±1mV(ORP) | |
Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
Repeatability | ±0.1pH, ±10mV(ORP) | |
Response time | ≤60 seconds | |
Recommended maintenance period | 1-3 months | |
Temperature | Range | -20℃ – 85℃ |
Resolution | 0.1℃ | |
Accuracy | ±0.5℃ | |
Repeatability | ≤0.5℃ | |
Response time | ≤25 seconds | |
Recommended maintenance period | 12 months | |
Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
Accuracy | ±1.5%FS | |
Repeatability | ≤0.5%FS | |
Response time | ≤30 seconds | |
Recommended maintenance period | 3-6 months | |
Dissolved oxygen (Optional) | Range | 0-20mg/L |
Accuracy | ±0.3mg/L | |
Repeatability | ≤±1.5% | |
Response time | ≤30 seconds | |
Recommended maintenance period | 1-3 months | |
Expansion port | Port type | RS485、4-20mA、0-5V |
Item | Index | Value |
System | working power | (220±22)V AC,(50±1)Hz |
Power | 30W | |
Cabinet size | 800mm*506mm*180mm (standard version) | |
Weight | about 15Kg | |
Storage temperature | 4℃~+50℃ | |
Working temperature | 4℃~+50℃ / -25℃~+50℃(optional temperature control heating antifreeze module) | |
Working humidity | ≤95%RH (no condensation) | |
Inlet flow | 500~1000 mL/min | |
Inlet pressure | < 3kg/cm³ | |
Communication interface | RS485 Modbus RTU communication protocol + wireless interface | |
Turbidity | Range | 0-1NTU / 0-20NTU / 0-100NTU / 0-4000NTU |
Resolution | 0.001NTU | |
Lower detection limit | 0.02NTU;0.1NTU(0-4000NTU) | |
Zero drift | ≤1.5% | |
Indication stability | ≤1.5% | |
Accuracy | 2% or ±0.02NTU;5% or 0.5NTU(0-4000NTU) | |
Repeatability | ≤3% | |
Response time | ≤60s | |
Recommended maintenance period | 3-12 months (depending on the water quality on site) | |
Residual chlorine/chlorine dioxide | Range | 0-5mg/L / 0-20mg/L |
Resolution | 0.01mg/L | |
Lower detection limit | 0.05mg/L | |
Accuracy | ±0.05mg/L or ±5% (DPD comparison error ±10%) | |
Response time | ≤120 seconds | |
Recommended maintenance period | 1-3 months or weekly calibration, 3-6 months to replace consumables | |
PH /ORP(optional) | Range | 0-14pH, ±2000mV(ORP) |
Resolution | 0.01pH, ±1mV(ORP) | |
Accuracy | ±0.1pH, ±20mV(ORP)or ±2% | |
Repeatability | ±0.1pH, ±10mV(ORP) | |
Response time | ≤60 seconds | |
Recommended maintenance period | 1-3 months | |
Temperature | Range | -20℃ – 85℃ |
Resolution | 0.1℃ | |
Accuracy | ±0.5℃ | |
Repeatability | ≤0.5℃ | |
Response time | ≤25 seconds | |
Recommended maintenance period | 12 months | |
Conductivity (Optional) | Range | 1-2000uS/cm / 1~200mS/m |
Accuracy | ±1.5%FS | |
Repeatability | ≤0.5%FS | |
Response time | ≤30 seconds | |
Recommended maintenance period | 3-6 months | |
Dissolved oxygen (Optional) | Range | 0-20mg/L |
Accuracy | ±0.3mg/L | |
Repeatability | ≤±1.5% | |
Response time | ≤30 seconds | |
Recommended maintenance period | 1-3 months | |
Expansion port | Port type | RS485、4-20mA、0-5V |
-
Introduction
The Multi-parameter analyzer can be widely used in urban or rural water supply plants, tap water pipeline networks, tap water secondary water supply, user taps, indoor swimming pools, Online monitoring of water quality such as large-scale water purification equipment and direct drinking water is an indispensable online analysis equipment in the fields of water plant production process control, water conservancy and water management, and sanitation supervision.
Product detail pictures:
Related Product Guide:
We've got a really efficient group to deal with inquiries from prospects. Our purpose is "100% customer fulfillment by our product excellent, price & our group service" and enjoy a superb track record amid clientele. With many factories, we can easily deliver a wide selection of Online Ph Sensor Factory – Sinomeasure Multi-parameter analyzer – Sinomeasure , The product will supply to all over the world, such as: St. Petersburg, Denver, Singapore, Based on our automatic production line, steady material purchase channel and quick subcontract systems have been built in mainland China to meet customer's wider and higher requirement in recent years. We are looking forward to cooperating with more clients worldwide for common development and mutual benefit!Your trust and approval are the best reward for our efforts. Keeping honest, innovative and efficient, we sincerely expect that we can be business partners to create our brilliant future!
By Anna from US - 2018.07.12 12:19
Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!