head_banner

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We believe in: Innovation is our soul and spirit. Quality is our life. Shopper need is our God for Pressure Transducer, Turbidity Analyzer, Tss Analysis, With advantage of industry management, the business has generally been committed to supporting prospects to become the current market leader in their respective industries.
Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure Detail:

  • Specification
 Product Artificial Intelligence PID Regulator
 Model SUP-2300
 Dimension A. 160*80*110mm
B. 80*160*110mm
C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F. 72*72*110mm
H. 48*48*110mm
K. 160*80*110mm
L. 80*160*110mm
M. 96*96*110mm
Measurement accuracy ±0.2%FS
Transmission output Analog output—-4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V
Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistive load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supply AC/DC100~240V (Frequency 50/60Hz)  Power consumption≤5W
DC 12~36V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing
Printout RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions

 

  • Introduction

Artificial intelligence PID regulator adopts advanced experts PID intelligence algorithm, with high control precision, no overshoot, and fuzzy self-tuning function. The output is designed as modular architecture; you can acquire various control types by replacing different function modules. You can choose PID control output type as any of current, voltage, SSR solid state relay, single / three-phase SCR zero-over triggering and so on. Besides it has another two ways alarm output, and optional transmission output, or standard MODBUS communication interface. The instrument can replace the servo amplifier in driving the valve (valve position control function) directly, external given function, and manual / automatic no-disturbance switch function.

With multiple types of input functions, one instrument can be used with different various input signals, reducing the number of instruments greatly. It has a very good applicability, and can be used with various types of sensors, transmitters used in conjunction to achieve on the temperature, pressure, liquid level, capacity, power and other physical quantities measurements show that, and with all the various actuators on the electrical and electromagnetic heating equipment, electric valves PID regulation and control, alarm control, data acquisition functions.

 

Input
Input signals Current Voltage Resistance Thermocouple
Input Impedance ≤250Ω ≥500KΩ    
Maximum input current 30mA      
Maximum input voltage   <6V    
Output
Output signals Current Voltage Relay 24V Distribution or feeder
Output load capability ≤500Ω ≥250 KΩ

(Note: Please replace the module for higher  load capacity)

AC220V/0.6(small)

DC24V/0.6A(small)

AC220V/3A(big)

DC24V/3A(big)

According to Remarks

≤30mA
Adjustive output
Control output Relay Single-phase SCR Dual-phase SCR Solid relay
Output load AC220V/0.6A(small)

DC24V/0.6A(small)

AC220V/3A(big)

DC24V/3A(big)

According to Remarks

AC600V/0.1A AV600V/3A

(Should be remarked if driven directly)

DC 5-24V/30mA
Comprehensive parameter
Accuracy 0.2%FS±1word
Setting model Panel touch key

parameter setting values locking;

store the setting values permanently

Display style -1999 ~ 9999 measured values, set values, external given values display;

0~100% valve position display

0 ~ 100% output values display;

LBD display for working state

Working environment Ambient temperature: 0 ~ 50 ;

Relative humidity: ≤ 85% RH;

Far from strong corrosive gas

Power supply AC 100 ~ 240V(switching power), (50-60HZ);

DC 20 ~ 29V

Power ≤5W
Frame Standard snap-on
Communication Standard MODBUS communication protocol,

RS-485, communication distance up to 1 km,

RS-232 ,communication distance up to 15 meters

Note: While with communication function, the communication converter should be a active one.

Note: The output load capacity of external dimensions D, E instrument relay is the AC220V/0.6A, DC24V/0.6A


Product detail pictures:

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure detail pictures

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure detail pictures

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure detail pictures

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure detail pictures

Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure detail pictures


Related Product Guide:

We consistently carry out our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management promoting benefit, Credit attracting customers for Reasonable price Ultrasonic Flow - SUP-2300 Artificial Intelligence PID Regulator – Sinomeasure , The product will supply to all over the world, such as: Tunisia, Johannesburg, Iraq, Our mission is "Provide Products with Reliable Quality and Reasonable Prices". We welcome customers from every corner of the world to contact us for future business relationships and achieving mutual success!
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Adelaide from Montreal - 2018.12.11 11:26
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Elma from Cyprus - 2018.12.14 15:26