head_banner

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

The business keeps to the operation concept "scientific management, premium quality and efficiency primacy, customer supreme for Flanged Flow Meter, Sludge Flow Meter, Water Flow Sensor Price, We sincerely welcome overseas consumers to consult for your long-term cooperation as well as the mutual advancement.We strongly think that we will do superior and far better.
Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure Detail:

  • Specification
 Product Single-loop digital display controller
 Model SUP-2100
 Dimension A. 160*80*110mm
B. 80*160*110mm
C. 96*96*110mm
D. 96*48*110mm
E. 48*96*110mm
F.72*72*110mm
H. 48*48*110mm
K.160*80*110mm
L. 80*160*110mm
M. 96*96*110mm
Measurement accuracy ±0.2%FS
Transmission output Analog output—-4-20mA、1-5v、
0-10mA、0-5V、0-20mA、0-10V
Alarm Output ALM—-With upper and lower limit alarm function, with alarm return difference setting;Relay capacity:
AC125V/0.5A(small)DC24V/0.5A(small)(Resistive load)
AC220V/2A(big)DC24V/2A(big)(Resistive load)
Note: When the load exceeds the relay contact capacity, please do not directly carry the load
Power supply AC/DC100~240V (Frequency 50/60Hz)  Power consumption≤5W
DC 12~36V  Power consumption≤3W
Use environment Operating temperature(-10~50℃)No condensation, no icing
Printout RS232 printing interface, micro-matched printer can realize manual, timing and alarm printing functions

 

  • Introduction

Single-loop digital display controller with automatic SMD packaging technology, has a strong anti-jamming capability. Designed with dual-screen LED display, it could display more contents. It  can be used in conjunction with various sensors、transmitters to display temperature, pressure, liquid level, speed, force and other physical parameters, and to output alarm control, analog transmission, RS-485/232 communication etc. More than the traditional digital display meters is a new function to restore the factory default parameters, with easier operation and better applicability.

Input signal type list:

Graduation Number Pn Signal type Measure range Graduation Number Pn Signal type Measure range
0 TC B 400~1800℃ 18 Remote Resistance 0~350Ω -1999~9999
1 TC S 0~1600℃ 19 Remote Resistance 3 0~350Ω -1999~9999
2 TC K 0~1300℃ 20 0~20mV -1999~9999
3 TC E 0~1000℃ 21 0~40mV -1999~9999
4 TC T -200.0~400.0℃ 22 0~100mV -1999~9999
5 TC J 0~1200℃ 23 -20~20mV -1999~9999
6 TC R 0~1600℃ 24 -100~100mV -1999~9999
7 TC N 0~1300℃ 25 0~20mA -1999~9999
8 F2 700~2000℃ 26 0~10mA -1999~9999
9 TC Wre3-25 0~2300℃ 27 4~20mA -1999~9999
10 TC Wre5-26 0~2300℃ 28 0~5V -1999~9999
11 RTD  Cu50 -50.0~150.0℃ 29 1~5V -1999~9999
12 RTD  Cu53 -50.0~150.0℃ 30 -5~5V -1999~9999
13 RTD  Cu100 -50.0~150.0℃ 31 0~10V -1999~9999
14 RTD  Pt100 -200.0~650.0℃ 32 0~10mA square -1999~9999
15 RTD  BA1 -200.0~600.0℃ 33 4~20mA square -1999~9999
16 RTD  BA2 -200.0~600.0℃ 34 0~5V square -1999~9999
17 Linear resistance 0~400Ω -1999~9999 35 1~5V square -1999~9999

Product detail pictures:

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures

Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure detail pictures


Related Product Guide:

The pretty loaded projects management experiences and one to a person support model make the high importance of business enterprise communication and our easy understanding of your expectations for Top Quality 4 20ma Signal Generator - SUP-2100 Single-loop digital display controller – Sinomeasure , The product will supply to all over the world, such as: Monaco, Vietnam, Germany, Our professional engineering group will always be ready to serve you for consultation and feedback. We are able to also offer you with absolutely free samples to meet your requirements. Finest efforts will likely be produced to give you the ideal service and goods. For anyone who is thinking about our company and merchandise, please contact us by sending us emails or contact us quickly. As a way to know our merchandise and firm. lot more, you can come to our factory to find out it. We'll always welcome guests from all over the world to our business to build company relations with us. Please feel free to get in touch with us for business and we believe we are going to share the top trading practical experience with all our merchants.
  • It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Lee from Macedonia - 2018.11.02 11:11
    Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Sharon from Afghanistan - 2018.09.19 18:37